Hand-held Analyzer 2250 Light User Manual160
Instantaneous Measured Spectra
‡‡
•L
WF
•L
WS
B.4.1 Processed Parameters for Display Only
The following general parameter is available for display for Total data:
Time Remaining (for the current measurement, taking available disk space into account)
The following ISO/EU Occupational Health Parameters are calculated and displayed for Total,
Periodic Reports and Logged data:
•L
ep,d
•L
ep,d,v
If Statistics are available, then Std.Dev. and 7 percentile levels can be calculated and displayed:
LXN1 or LXUN1 to LXN7 or LXUN7.
If L
Weq
spectrum is available, then NC, NC Decisive Band, NR, NR Decisive Band, RC, RC
Classification, NCB, NCB Classification can be calculated and displayed.
If L
Weq
1/3-octave spectrum is available, then Loudness and Loudness Level can be calculated
and displayed.
B.4.2 Relationship Between Setup and Measurement Parameters
The measurement parameters are measured in accordance with the setup parameters.
Table B.1 through Table B.3 describe the relationship between the setup and measurement
parameters:
‡‡. These parameters require a license for BZ-7223 and measurement of spectra.
Table B.1 General Parameters
Parameter LXeq LXE LXIeq LAFTeq LVpeak TVpeak LXYmax LXYmin
Sound Field
Correction

Windscreen
Correction

Broadband
(excl. Peak)

Broadband
Peak
