APPENDIX A
Setup Parameters
149
A.10 Occupational Health
Post-recording
Time
0 to 300 s Use this parameter to specify how much extra you want to be
recorded after the trigger conditions are no longer fulfilled
Duration Limit
On
Off
Use this parameter to enable the Minimum Duration and
Maximum Duration parameters for overruling the duration of
the signal recording determined by the trigger condition
parameters
Minimum Duration
00:00:00 to
01:00:00
When Duration Limit is On, then Minimum Duration will
determine the minimum recording time regardless of the
trigger conditions
The total record length will then (as a minimum) be the sum of
Minimum Duration, Pre-recording Time and Post-recording
Time
Maximum Duration
00:00:00 to
01:00:00
When Duration Limit is On, then Maximum Duration will
determine the maximum recording time regardless of the
trigger conditions.
The total record length will then (as a maximum) be the sum of
Maximum Duration, Pre-recording Time and Post-recording
Time.
Note: If Maximum Duration = 00:00:00, then it is disabled and
does not limit the duration
*. Requires license for Signal Recording Option BZ-7226.
†. For Logging BZ-7133 template only.
Table A.11 Occupational health parameters
Parameter Values Comment
Exposure Time 00:01:00 to
1.00:00:00
Set the Exposure Time to the actual time that
you are exposed to noise during a workday.
Used for calculation of L
ep,d
and L
ep,d,v
.
Note: Exposure Time can be changed after the
measurement has been done
Reference Time 00:01:00 to
5.00:00:00
Set the Reference Time as required for
calculation of Sound Exposure Level or Time
Weighed Average with a reference time other
than 8 hours.
Used for calculation of L
ep,d,v
and TWA
v
Table A.10 (Cont.) Signal Recording parameters
*
Parameter Values Comment
Przeglądanie stron 156