B&K CT310 Instrukcja Użytkownika Strona 36

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 48
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 35
CT600/602/610 and CT300/310 BKC-DIP Product Specific Appendices
Version 2.00.09
Updated 12/15/06
Page 36 of 48
Appendix L, X (executive) Commands
The following is a list of the supported Executive commands and details regarding their usage:
Recall Preset Command: (receiveID, X, 0, z=nn; cs16)
Zone z Preset nn is recalled to the current preset. Similar to the "G" get and “S” set commands,nn
can range from 00h FDh, however it CANNOT be FFh for the current preset (as recalling the
current preset has no meaning).
NOTE: nn of FE is reserved for future expansion.
(00, X, 0, 1=4;cs16) Recall Zone 1 Preset 4 to current preset
(00, X, 0, 2=7;cs16) Recall Zone 2 Preset 7 to current preset
Save Preset Command: (receiveID, X, 1, z=nn, autoNameMode; cs16)
The current preset is saved to Zone z Preset nn. . Similar to the "G" get and “S” set commands, nn
can range from 00h FDh, however it CANNOT be FFh for the current preset (as saving the
current preset has no meaning).
NOTE: nn of FE is reserved for future expansion.
(00, X, 1, 1=3;cs16) Save current preset to Zone 1 Preset 3
(00, X, 1, 2=9;cs16) Save current preset to Zone 2 Preset 9
The autoNameMode specifier can take on the following values with the following meanings:
0 Auto Name Preset, based upon state of System parameter Preset Auto
Naming
1 Do not Auto Name, regardless of System parameter Preset Auto
Naming
2 Force Auto Name, regardless of System parameter Preset Auto Naming
(00, X, 1, 1=8, 0;cs16) Save current preset to Zone 1 Preset 8
Auto Name based on Preset Auto Naming parameter
(00, X, 1, 1=8, 1;cs16) Save current preset to Zone 1 Preset 8
Do not Auto Name, preserve Preset Title
(00, X, 1, 1=8, 2;cs16) Save current preset to Zone 1 Preset 8
Force Auto Naming, overwriting Preset Title
NOTE: If Preset Auto Naming is active, the preset title will be overwritten.
NOTE: The autoNameMode specifier is optional. If it is omitted its value defaults to 0, so the
preset title is Auto Named based on the state of the System parameter Preset Auto
Naming.
Power State Command: (receiveID, X, 2, z=onOff; cs16)
Zone z’s power state may be controlled using this command. The onOff parameter may take on
the values of 1 or 0 for “on” or “off (Sleep)” respectively.
Przeglądanie stron 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 47 48

Komentarze do niniejszej Instrukcji

Brak uwag