Note 27: In the current CT series there is a Dedicated Zone input
associated with each Zone Output. Thus, these values are the
same as the Output Bitmap parameters. They are provided in
the protocol for future expandability should there be a
difference between Zone Dedicated inputs and Zone Outputs.
Note 28: The MSB and LSB form a 16 bit value indicating how much
Serial Macro free space currently remains in the unit.
26=8 (MSB)
27=0 (LSB)
Indicates 800h (2048 decimal) bytes free remaining serial
macro space.
26=1 (MSB)
27=E4 (LSB)
Indicates 1E4h (484 decimal) bytes free remaining serial macro
space.
Note 29: 0h = No RF Remote support, 1h = RF Remote supported
Note 30: String containing list of all Group Code Sets (Zone IDs)in the
unit. Each Code Set (Zone ID) is delimited by white space,
and the values are in hexadecimal.
For example:
“0 B C D E F 10 0 0 0 0 0 0 0 0 0 0”
indicates that there are 17 Groups with Code Sets (Zone IDs):
Group Code Set (Zone ID)
0 0h
a 3h
b 4h
c Bh
d Ch
e Dh
f Eh
g 10h
h 0h
i 0h
j 0h
k 0h
l 0h
m 0h
n 0h
o 0h
p 0h
q 0h
r 0h