CT600/602/610 and CT300/310 BKC-DIP Product Specific Appendices
Version 2.00.09
Updated 12/15/06
Page 20 of 48
Below is an example of how the RS-232 Feedback Selection
Update may be used to allow Volume Feedback from the
CT610/310/600 for use with an external controller.
Step 1)
First, set the CT300/310/600/602/610 System Parameter AE = 1,
RS-232 Feedback Selection set to Update.
Next, initiate a Master Volume change by any one of the
following methods:
B&K code set 11 (Logical Zone 11) IR Master Volume Up B&K code
set 11 (Logical Zone 11) IR Master Volume Down Front Panel
Volume Encoder up or down while set to Logical Zone 11
Using an IR remote control set to B&K code set 11 (Logical
Zone 11) a user presses the Master Volume + (Up) button.
The CT610/310/600 will generate the following BKC-DIP Update
message command:
(0,U,I,0B=C4;) Update from Zone 11 via an IR message.
Step 2)
The external control device should be set to Poll for any BKC-
DIP Update messages and parse out the specific BKC-DIP message
of interest, in this case a Zone 11, IR Master Volume + (1=C4)
“U,I,0B=C4”. Note if another means of Master Volume up is
used, such as the Front Panel Encoder Up, this would require a
different message “U,F,0B=0B”.
Step 3)
The external controller should generate a
CT300/310/600/602/610 Get command for the specific current
Preset Parameter of interest, in this case the current Preset
Parameter Volume value. The command would look like the
following BKC-DIP Get message:
(0,G,P0B=FF,1;) Get Zone 11 Volume setting.
Step 4)
Once the CT300/310/600/602/610 receives the above Get message
it will generate a Reply message with the requested parameter,
in this case the Reply for the current Preset Parameter Volume
value for Zone 11. The command would look like the following
BKC-DIP Reply message command:
(0,R,P0B=FF,1=28;) Zone 11 current Preset Volume value is set
to 28 hex or 0dB.
Step 5)
The external controller may then use the CT300/310/600/602/610
Zone 11 current Preset Parameter Volume value of “28 hex to
update its GUI or status in an appropriate fashion.
In addition to RS-232 Feedback Selections of Update and Reply,
Disable and Both (Update and Reply) allow further versatility
to set the best interface for the CT300/310/600/602/610 to an
external controller.