CT600/602/610 and CT300/310 BKC-DIP Product Specific Appendices
Version 2.00.09
Updated 12/15/06
Page 15 of 48
For example,
(0,S,S,7E=0,94=04;cs16)
7E=0 indicates Zone C’s control out state is based on the
RS-232 Control out register (94h)
94=04 indicates that Zones A, B, D, E, and F control out
will be off (only if their appropriate Control Output
settings (identifiers 7Ch – 81h) are set to use RS-232),
and that Zone C’s control output would be On (since its
Control Output setting 74h = 0, RS-232) and bit 2 of the
RS-232 Control out register (94h) is set.
Note 14: 0h = Off
1h = switch to Input 1
2h = switch to Input 2
3h = switch to Input 3
4h = switch to Input 4
5h = switch to Input 5
6h = switch to Input 6
7h = switch to Input 7
8h = switch to Input 8
9h = switch to Input 9
Ah = Reduce Volume
Note 15: 0h = Audio only, 1h = Video only, 2h = Audio and Video
Note 16: *0h = Audio sense
*1h = Video sense
*2h = Audio or Video sense
3h = Common Control (1 for Page/Event 1, 2 for Page/Event 2)
4h = RS-232
*Note: 0h, 1h and 2h are not valid Page/Event Activation
settings while the Page/Event Action is set to Ah “Reduce
Volume” see Note 14 listed above.
Note 17: Release Time in 1 second increments.
0h = 0 seconds, 1h = 1 second, 2h = 2 seconds, … 19h = 25
seconds, 1Ah = forever
Note 18: 0h = Off, 1h = Dim, 2h = Medium, 3h = Bright
*Note: Front brightness commands do not apply to a
CT600/602/300.
Note 19: 0h = “ENTER” Button required to recall Favorite Preset,
1h = Automatically recall Favorite Preset
Note 20: 0h = Disabled, 1h = Enabled
*Note: Front panel does not apply to a CT300/600/602.
Note 21: 0h = 1200
1h = 2400
2h = 9600
3h = 14400
4h = 19200
5h = 28800
6h = 38400
7h = 57600
8h = 115200
Note 22: Valid IDs are 00h to 7Fh. Receive IDs must be unique (to
avoid ambiguity)
Note 23: 0h = Hidden, 1h = Visible
Note 24: 00h to 7Fh map directly to Transmit IDs 00h to 7Fh. 80h maps
to the Global Transmit ID FFh.