Feature
SLM
Software
Frequency
Analysis
Software
Logging
Software
Enhanced
Logging
Software
Back-erase – last 5 seconds of measurement data

120+ dB Dynamic Range – no need for range switching

Sound levels up to 140 dB with supplied Microphone Type 4189

Sound levels up to 152 dB using Microphone Type 4191

IEC/ANSI SLM standards Type/Class 1

Frequency weightings A, B, C, Z (linear) and time weightings F, S, I

Free-field/diffuse-field correction

Automatic windscreen detection and correction

Preset time start/stop

Multi-language user interface

Context-sensitive help

Voice, metadata and text annotation of measurements

Display color-schemes optimised for day, night, indoor and outdoor use

Personal login – protects your personal setups from other users

Broadband statistics based on L
Aeq
, L
AF
or L
AS

Broadband frequency range: 3 Hz – 20 kHz

Remote control using GPRS/EDGE/3G modem

Transfer of data files while measuring (USB, LAN or modem)

Recording of measured signal during measurement
*
*
*
*
Timers for automatic start of measurement

Occupational health parameters

Weather data and GPS input

Tone assessment

1/1-octave spectra (centre frequencies 8 Hz to 16 kHz)
1/3-octave spectra (centre frequencies 6.3 Hz to 20 kHz)

Spectral statistics based on L
AF
or L
AS

Loudness and Noise Rating results

Charge Injection Calibration (CIC)

Level triggers and recordings

Logging of all or selected broadband parameters and spectra

Logging period 1 s to 24 h

L
Aeq
, L
AS
, L
AF
logged every 100 ms

Profile display

Profile overview of entire measurement

Markers on profile display

Recording of signal during noise events
*
*
Periodic reports of all measured data
Report period 1 min to 24 h
Timer trigger for recordings
L
dn
, L
den
, L
day
, L
evening
, L
night
Continuous measurement
*
If Signal Recording Option is enabled
If Frequency Analysis Software is enabled
Przeglądanie stron 10